In the field of industrial production, the burner is a supporting equipment required for many major projects, and fine adjustment of the burner is required before it is put into use. Lack of scientific installation and commissioning of the burner. EBICO has dozens of first-line after-sales service engineers, and has accumulated rich experience about the use of burners.
The use of burners at the start-up level
1. Carefully check whether the fuel meets the requirements of the burner before commissioning; check whether the testing instrument of the gas supply pipeline is normal and whether the opening and closing of the pipeline valve is normal.
2. Check carefully the installation reliability and sealing of all newly installed pipelines.
3. Ensure that the gas supply volume and gas supply parameters meet the requirements of safe combustion.
4. Guide the operators to read the manual of combustion equipment carefully and master the safety operation knowledge and methods.
5. Check whether the gas valve is open before each start.
6. Start the power control button on the control cabinet, start the fan control button, when the combustion fan works without abnormal phenomenon, then start the combustion control button, at this time the combustion program controller starts to work, through a certain program for ignition, gas delivery, flame detection, etc. to finally achieve safe combustion.
7. When the combustion controller receives a signal unfavorable to combustion (example: ignition failure, unstable air pressure, circuit problems), the combustion controller immediately turns off the gas and issues an alarm signal to solve the fault by the operator to manually reset it.
8. The whole operation process, the operator refers to the furnace safety operating procedures and production process requirements for operation.
Use of burner at shutdown level
1. The furnace temperature reaches the set value automatically shut down, the operator does not need to operate, wait until the furnace temperature is lower than the set value when the controller is automatically turned on.
2. Man-made shutdown and shift shutdown, the operator operates the shutdown in the prescribed order (a. first turn off the combustion control button, b. then turn off the fan button, c. finally turn off the power button).
3. Turn off the operator to close the gas pipeline valve in case of long shutdown time to avoid gas leakage.
Scientific and reasonable operation of the burner installation, commissioning, can better play the performance advantages of the burner equipment, but also can effectively extend the service life of the burner. Get more burner use, maintenance, maintenance tips, welcome to call +86-510-85187552.